Pressure relief valve for water heater
The safety relief valve ensures the safe use of the water heater and prevents the pressure from increasing.
The use of a safety relief valve prevents major damage to the system in the event of excessive pressure.
The safety relief valve works in such a way that if the pressure in the water rises above 8 bar, it only releases the water and consequently reduces the pressure in the system.
Application: installation in the boiler inlet (water heater).
Trusted client
Trusted delivery
1. Brass construction acc/ UNE-EN 12165 nickel plated.
2. Gas (BSP) threaded M-F ends acc/ ISO 228/1.
3. Maximum working pressure 16 bar (PN 16).
4. Working temperature from -20ºC to 110ºC
5. Standard tare at 8 bar ±0.5 bar.
6. Outlet for hose connection.
16 other products in the same category:
Flanged type balancing valve – fixed orifice PN16
GENERAL CHARACTERISTICS Range: from DN65 to DN600. -Design according to BS7350:1990 standard. -Model incorporating a callibrated orifice plate on the inlet flange allowing fixed flow measurement, regulation and cut off function -Oblique seat ensuring excellent adjustment precision. -Flow measurement accuracy of +/-5% at any open valve position in accordance with BS7350. -Opening indicator with...
BSE threaded bronze balancing valve PN20
The proposed valves have an oblique seat which offers a good adjustment precision and a resistance lower than the valves with a straight seat: head losses are small, flow more important for a same DN leads. Mounting on pipes is preferred direction indicated by an arrow on the body. The balancing valve can be used as a « stop valve. A thrust allows memorizing the valve adjustment, without...
Static balancing valve
1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages: - Micrometric adjusting of the transfer flow. - Indicator of calibration reading of numerical value on the valve's hand wheel. - Possibility of checking circuit via indirect measuring of flow rate using...
Expansion tank 8l 1"
USE: The 8-liter expansion tank for cold water is designed to be mounted on a small hydrophoric pump with accessories. As a result of such assembly, we get a very compact and small hydrophore set. Multipurpose tank with replaceable membrane for closed heating systems. An expansion tank with a replaceable membrane is one of the elements of protection of closed central heating systems....
Thermostatic kit with divert valve and mixer
1. Pre-assembled thermostatic kit. 2. Facilitates the connection from the solar panel to the boiler and simplifies the installation. 3. Thermostatic mixer valve with lime protection. 4. Diverter thermostatic valve with preset temperature at 40ºC. 5. Connectors included. 6. Non return valve with stainless steel filter. 7. Maximum water inlet temperature 110ºC.
Stainless steel manifold
Body of Stainless Steel AISI 304L Connection parts of brass CW617N EPDM seals and silent blocks Polymer Hand wheels and caps Derivation connection: G 3/4” (ISO 228) EUROKONUS Connections on line: Female 1" (ISO 228) Max. working pressure: 6 bar Max circuit test pressure: 10 bar (at 20°C) Differential pressure Δp max.: 1 bar Maximum working temperature: 70°C Fluid allowed: Water or Water +...
Magnetic filter for boilers
1. Compact magnetic filter for boilers 2. Body construction in polyamide PA66 + 33% Glass Fiver 3. Cap construction in polyamide PA66 + 33% Glass Fiver 4. Stainless steel filter AISI 304, 800 microns 5. EPDM PEROX as a hydraulic seal 6. Magnetic element Neodymium RE35 11.000 Gauss. 7. Brass ball valve acc/ UNE-EN 12165 8. Brass connection fitting acc/ UNE-EN 12165 9. Maximum working pressure 3...
3 way motorized-zone valve with 5 cores wire
1. The zone valve is intended for use in control terminal units such as fan-coil and boxes in heating, ventilation, and air conditioning systems. 2. The valves can be used with hot and cold water in the temperature range from 0 ºC (nonfreezing) to 94 ºC. 3. The valve is driven by hysteresis synchronous motor with spring return. 4. There are two types of motorized valves: normally closed 2-way...
Polymer manifold
1. The Polymer manifold for floor systems enables parallel feed of terminal fluidic terminals. 2. Limited dimensions that enable the insertion in boxes to be walled in partitioning walls 3. Manual or automatic on-off interception of the single circuits. 4. Adjustment of the flow in transit for balancing between the various circuits by means of flowmeters mounted on the manifold and equipped...
Static balancing valve PN20
1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages: • Micrometric adjusting of the transfer flow. • Indicator of calibration reading of numerical value on the valve's hand wheel. • Possibility of checking circuit via indirect measuring of flow rate using...
Expansion tank with manometer 80l 1"
APPLICATION: Horizontal diaphragm tank 80l. with a pressure gauge for cold water is designed to be assembled with a pump with medium-capacity accessories. As a result of such completion and after adding an anti-vibration hose with an elbow, we get a compact and relatively small hydrophore set. Additional equipment of the tank with a manometer mounted in its part where there is an air cushion...
Balancing valve regulation unit PN16
WORKING CONDITIONS Maximum working pressure : 16 bar. Maximum working temperature : - 20°C / + 110°C. STANDARDS Pressure tests according to standards: EN 12266-1, DIN 3230, BS 6755 and ISO 5208 Body : 24 bar. Seat : 17.6 bar. Flange connection according to EN 1092-2 : ISO PN16.
Flanged type balancing valve – fixed orifice PN25
GENERAL CHARACTERISTICS Range: from DN65 to DN600. -Design according to BS7350:1990 standard. -Model incorporating a callibrated orifice plate on the inlet flange allowing fixed flow measurement, regulation and cut off function -Oblique seat ensuring excellent adjustment precision. -Flow measurement accuracy of +/-5% at any open valve position in accordance with BS7350. -Opening indicator with...
Divert thermostatic valve
1. Divert hot water coming from the panel towards the boiler and the consumption. The ratio will be in function of inlet temperature. 2. Setting temperature 40ºC. 3. Thermostatic unit with lime protection and highspeed response. 4. Maximum water inlet temperature 110ºC. 5. Maximum working pressure 10 bar. 6. Flow rate 45 l/min. at pressure 3 bar.