1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages:
- Maintaining a constant flow rate at the device value, within a differential pressure range between upstream and downstream
- The flow rate value is set through a cartridge adjustable to ensure the design flow...
GENERAL CHARACTERISTICS
Range: from DN65 to DN600.
-Design according to BS7350:1990 standard.
-Model incorporating a callibrated orifice plate on the inlet flange allowing fixed flow measurement, regulation and cut off function
-Oblique seat ensuring excellent adjustment precision.
-Flow measurement accuracy of +/-5% at any open valve position in accordance with BS7350.
-Opening indicator with...
1. The Polymer manifold for floor systems enables parallel feed of terminal fluidic terminals.
2. Limited dimensions that enable the insertion in boxes to be walled in partitioning walls
3. Manual or automatic on-off interception of the single circuits.
4. Adjustment of the flow in transit for balancing between the various circuits by means of flowmeters mounted on the manifold and equipped...
1. Variable orifice cast iron double regulating globe valve according to BS 7350 standard.
2. Designed to regulate and balance the flow in heating and cooling with high precision, which means a more uniform temperature distribution.
3. Body and Bonnet in Ductil Iron.
4. PN16 flanges according to EN 1092.
5. Face to Face according to EN558-1 series 1.
6. Non-rising stem. Compact design.
7. EPDM...
1. Multifunction magnetic filter for hydraulic circuits
2. Polyamide PA66 + 30% FV diverter body
3. Cartridge body in polyamide PA66 + 30% FV
4. Cap construction in polyamide PA66 + 33% FV
5. Stainless steel filter AISI 304, 800 microns
6. EPDM PEROX as a hydraulic seal
7. Magnetic element Neodymium RE35 11.000 Gauss.
8. Brass ball valves according UNE-EN 12165
9. Manual air vent valve on...
Preset at the factory for distributing sanitary hot water at about 45°C, and are provided of special valves ECO to be inspected with 3 functions:
– shut-off tap
– non-return valve
– stainless steel filter
If necessary modify the temperature it’s enough loosen the Hex calibration screw, rotate the handle and reading the immersion thermometer find out with precision the desired temperature.
The...
APPLICATION:
The 80l horizontal diaphragm tank for cold water is designed to be assembled with a pump with accessories. As a result of such assembly and after adding an anti-vibration hose with an elbow, we get a compact and relatively small hydrophore set. When selecting the size of the tank, it should be taken into account that the amount of water available between turning the pump off and...
The proposed valves have an oblique seat which offers a good adjustment precision and a resistance lower than the valves with a straight seat: head losses are small, flow more important for a same DN leads.
Mounting on pipes is preferred direction indicated by an arrow on the body. The balancing valve can be used as a « stop valve. A thrust allows memorizing the valve adjustment, without...
GENERAL CHARACTERISTICS
Range: from DN65 to DN600.
-Design according to BS7350:1990 standard.
-Model incorporating a callibrated orifice plate on the inlet flange allowing fixed flow measurement, regulation and cut off function
-Oblique seat ensuring excellent adjustment precision.
-Flow measurement accuracy of +/-5% at any open valve position in accordance with BS7350.
-Opening indicator with...
1. The zone valve is intended for use in control terminal units such as fan-coil and boxes in heating, ventilation, and air conditioning systems.
2. The valves can be used with hot and cold water in the temperature range from 0 ºC (nonfreezing) to 94 ºC.
3. The valve is driven by hysteresis synchronous motor with spring return.
4. There are two types of motorized valves: normally closed 2-way...
1. Pre-assembled thermostatic kit.
2. Facilitates the connection from the solar panel to the boiler and simplifies the installation.
3. Thermostatic mixer valve with lime protection.
4. Diverter thermostatic valve with preset temperature at 40ºC.
5. Connectors included.
6. Non return valve with stainless steel filter.
7. Maximum water inlet temperature 110ºC.
WORKING CONDITIONS
Maximum working pressure:16 bar
Maximum working temperature : -10°C / 120°C
STANDARDS
Flange connection according to EN 1092-2 ISO PN 16.
Test pressure according to EN 12266-1, DIN 3230, BS 6755 and ISO 5208.
1. Thermal insulation consisting of semi-casings and expanded polyethylene cover with external antiscratch film coating.
2. Half-bearings fixed with double-sided adhesive tape already applied.
3. Fire behaviour class 1
4. Density 33 Kg/mmᵌ
5. Max operating temperature -40° +90°
1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages:
• Micrometric adjusting of the transfer flow.
• Indicator of calibration reading of numerical value on the valve's hand wheel.
• Possibility of checking circuit via indirect measuring of flow rate using...
error Your review appreciation cannot be sent