

Reservoirs and retainers intended for drinking water are made of materials that have been certified for contact with drinking water. All components that are in the tank, retainer and that come into contact with drinking water also have certificates.
Trusted client
Trusted delivery
The advantage of flexible, quick-to-install tanks and reservoirs is their quick installation and cleaning, quality manufacturing and easy transportation. Nowadays, we are faced with constant weather changes. A certain period is very rainy and water is a problem for us, we can defend against it with Planteh portable flood barriers. During the sunny, warm period, it happens that there is a shortage of water in pumping stations and wells. Villages with smaller own water supply systems and reservoirs are particularly affected, where there is a shortage of drinking water in the summer, warm and dry months. Water is then brought in by firemen with tankers. In such cases, the fire brigade, civil protection, army, local residents or a construction company can quickly set up a flexible, quick-to-place tank, a reservoir for drinking water. These types of tanks are also useful in areas that are contaminated or in disaster areas where there have been spills of fuel, acids, bases or chemicals and other compounds and it takes time to restore them to their original state.
Properties of tanks, reservoirs:
- PZH CERTIFICATE - The tank jacket fabric and all its internal elements are approved for contact with drinking water, which is confirmed by the PZH hygiene certificate.
- BPA FREE - Tank fabric is made from BPA free materials.
- Easy transport: The tank can be moved easily and quickly
- Assembly in 30 minutes: After receiving the tank, simply unfold it on each side and easily install the connectors. After 30 minutes, the tank will be ready to fill!
- Resistance to UV radiation: PVC fabric is protected with a special varnish that extends its life when exposed to UV radiation.
- Durable fabric: A special technical fabric with a polyester mesh and a coating made of a PVC mixture ensures the necessary durability.
- No tools required: No tools are required to assemble the tank.
- Temperature resistance: The tanks are resistant to negative temperatures: up to -30°C.
- Custom tank: In addition to standard capacities, we offer custom tanks - so that they fit where you need them most.
- Welding with HF technology: The use of high-frequency (HF) welding ensures a permanent connection of fabrics at key points of the product.
Standard dimensions of tanks, reservoirs
V (l) |
A x B (m) |
6.000 |
3,90 x 3,50 |
12.000 |
5,93 x 3,90 |
25.000 |
6,25 x 5,93 |
30.000 |
7,50 x 5,93 |
50.000 |
8,05 x 7,95 |
60.000 |
9,10 x 8,30 |
75.000 |
8,65 x 10,11 |
100.000 |
10,0 x 10,11 |
150.000 |
11,70 x 12,13 |
200.000 |
14,85 x 12,13 |
250.000 |
18,20 x 12,13 |
16 other products in the same category:
Cooler with larger dimensions that provides high stability and durability. Great hygienic protection through a special shell with anti-vandalism finish. Height of the water jet can be regulated through the high precision valve. The separation between the push button and the water jet provides more comfort. Easily regulated cold water temperature (thermostat). Furthermore the possibility to...
Conventional spill tank are made of steel, stainless steel, plastic. Spill tanks made of these materials require the use of forklifts to move them to another location. Sometimes, however, moving is simply very difficult or impossible due to the dimensions. Flexible, quick-set spill tanks allow one worker to carry and set them up. By placing flexible containers under barrels, IBC tanks, tanks,...
Body of Stainless Steel AISI 304L Connection parts of brass CW617N EPDM seals and silent blocks Polymer Hand wheels and caps Derivation connection: G 3/4” (ISO 228) EUROKONUS Connections on line: Female 1" (ISO 228) Max. working pressure: 6 bar Max circuit test pressure: 10 bar (at 20°C) Differential pressure Δp max.: 1 bar Maximum working temperature: 70°C Fluid allowed: Water or Water +...
1. The zone valve is intended for use in control terminal units such as fan-coil and boxes in heating, ventilation, and air conditioning systems. 2. The valves can be used with hot and cold water in the temperature range from 0 ºC (nonfreezing) to 94 ºC. 3. The valve is driven by hysteresis synchronous motor with spring return. 4. There are two types of motorized valves: normally closed 2-way...
PKDS010 bench, steel tubes with a circular profile, hot-dip galvanized and plasticized, hardwood protected with the highest quality decorative-protective coating, 1800mm
The dryer is equipped with automation, which regulates and controls the drying of fruits, vegetables, herbs, pasta, laboratory samples, etc... The automation adjusts the operation of the dryer based on external factors and the fruits and products being dried. Due to complete automation, the drying device is very economical and fast. The automatic dryer protects the fruit from overheating, which...
Material: PVC Reinforcement: stainless steel Thickness: 8 mm Installation: on the pipe Fixing to the pipe: gasket
1. The Polymer manifold for floor systems enables parallel feed of terminal fluidic terminals. 2. Limited dimensions that enable the insertion in boxes to be walled in partitioning walls 3. Manual or automatic on-off interception of the single circuits. 4. Adjustment of the flow in transit for balancing between the various circuits by means of flowmeters mounted on the manifold and equipped...
Guaranteed for the use of cold and hot water80ºC Maximum Pressure: 8 bar20ºC Maximum Pressure: 16 barMinimum Temperature -10ºCNominal Pressure: PN 16 bar (200PSI)Threads according to ISO 228/1 (DIN259)Quick closing on both handles (1/4 turn)Packing gland in the stem Body and bonnet in nickel-plated brass (UNE EN 12165)
error Your review appreciation cannot be sent