The balancing valves are designed to realize exact regulations on heating and cooling systems. The entire threaded balancing valves RC 2106 range allows the fitter to measure the head losses and to control the installation flows with two instantaneous test points.
The proposed valves have an oblique seat which offers a good adjustment precision and a resistance lower than the valves with a straight seat: head losses are small, flow more important for a same DN leads.
Mounting on pipes is preferred direction indicated by an arrow on the body. The balancing valve can be used as a « stop valve. A thrust allows memorizing the valve adjustment, without disturbing the closure.
WORKING CONDITIONS
Maximum working pressure : 20 bar
Maximum working temperature : - 25°C / + 110°C.
Test pressure according to EN 12266-1, DIN 3230, BS 5154 and ISO 5208 :
Body : 30 bar.
Seat : 22 bar.
STANDARDS
BSP threaded connection according to ISO 228-1.
PL RC2106
No customer reviews for the moment.
error
Your review appreciation cannot be sent
feedback
Report comment
Are you sure that you want to report this comment?
check_circle
Report sent
Your report has been submitted and will be considered by a moderator.
error
Your report cannot be sent
Write your review
check_circle
Review sent
Your comment has been submitted and will be available once approved by a moderator.
Thermostatic mixing valve for centralized systems factory preset at about 45°C – possibility of choosing the temperature rotating the handle and reading the immersion thermometer mounted on the body of the mixer – anti-scalding safety device – nickel plated.
Hot maximum temperature: 85°C
Control range: 20-65°C
Maximum pressure: 10 bar
1. The zone valve is intended for use in control terminal units such as fan-coil and boxes in heating, ventilation, and air conditioning systems.
2. The valves can be used with hot and cold water in the temperature range from 0 ºC (nonfreezing) to 94 ºC.
3. The valve is driven by hysteresis synchronous motor with spring return.
4. There are two types of motorized valves: normally closed 2-way...
1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages:
• Micrometric adjusting of the transfer flow.
• Indicator of calibration reading of numerical value on the valve's hand wheel.
• Possibility of checking circuit via indirect measuring of flow rate using...
1. Variable orifice cast iron double regulating globe valve according to BS 7350 standard.
2. Designed to regulate and balance the flow in heating and cooling with high precision, which means a more uniform temperature distribution.
3. Body and Bonnet in Ductil Iron.
4. PN16 flanges according to EN 1092.
5. Face to Face according to EN558-1 series 1.
6. Non-rising stem. Compact design.
7. EPDM...
1. The balancing valve is a single component device having adjustment functions and that measures cold and hot fluids transiting inside closed and open systems with following advantages:
- Maintaining a constant flow rate at the device value, within a differential pressure range between upstream and downstream
- The flow rate value is set through a cartridge adjustable to ensure the design flow...
APPLICATION:
The 80l horizontal diaphragm tank for cold water is designed to be assembled with a pump with accessories. As a result of such assembly and after adding an anti-vibration hose with an elbow, we get a compact and relatively small hydrophore set. When selecting the size of the tank, it should be taken into account that the amount of water available between turning the pump off and...
APPLICATION:
The 24l horizontal diaphragm tank for cold water is designed to be assembled with a small pump with accessories (e.g. type WZ JY, JET). As a result of such completion and after adding an anti-vibration hose with an elbow, we get a compact and relatively small hydrophore set.
The tank uses a flexible diaphragm that divides the space in the tank into two parts. Water is stored in...
1. Multifunction magnetic filter for hydraulic circuits
2. Polyamide PA66 + 30% FV diverter body
3. Cartridge body in polyamide PA66 + 30% FV
4. Cap construction in polyamide PA66 + 33% FV
5. Stainless steel filter AISI 304, 800 microns
6. EPDM PEROX as a hydraulic seal
7. Magnetic element Neodymium RE35 11.000 Gauss.
8. Brass ball valves according UNE-EN 12165
9. Manual air vent valve on...
WORKING CONDITIONS
Maximum working pressure:25 bar
Maximum working temperature : -10°C / 120°C
STANDARDS
Flange connection according to EN 1092-2 ISO PN 25.
Test pressure according to EN 12266-1, DIN 3230, BS 6755 and ISO 5208.
Preset at the factory for distributing sanitary hot water at about 45°C, and are provided of special valves ECO to be inspected with 3 functions:
– shut-off tap
– non-return valve
– stainless steel filter
If necessary modify the temperature it’s enough loosen the Hex calibration screw, rotate the handle and reading the immersion thermometer find out with precision the desired temperature.
The...
1. Brass construction acc/ UNE-EN 12165 nickel plated.
2. Gas (BSP) threaded M-F ends acc/ ISO 228/1.
3. Maximum working pressure 16 bar (PN 16).
4. Working temperature from -20ºC to 110ºC
5. Standard tare at 8 bar ±0.5 bar.
6. Outlet for hose connection.
1. Thermal insulation consisting of semi-casings and expanded polyethylene cover with external antiscratch film coating.
2. Half-bearings fixed with double-sided adhesive tape already applied.
3. Fire behaviour class 1
4. Density 33 Kg/mmᵌ
5. Max operating temperature -40° +90°
Body of Stainless Steel AISI 304L
Connection parts of brass CW617N
EPDM seals and silent blocks
Polymer Hand wheels and caps
Derivation connection: G 3/4” (ISO 228) EUROKONUS
Connections on line: Female 1" (ISO 228)
Max. working pressure: 6 bar
Max circuit test pressure: 10 bar (at 20°C)
Differential pressure Δp max.: 1 bar
Maximum working temperature: 70°C
Fluid allowed: Water or Water +...